Curtis 1209/1221/1231
Connecting a Curtis 1209/1221/1231 motor driver

WARNING: SHOCK OR DAMAGE DANGER

The Curtis 1209/1221/1231 motor controllers do not provide isolation between the high voltage battery and the low voltage circuits.

Schematic diagram
Wiring diagram

The "Discharge OK +" output powers the motor controller. Should the BMS decide that the battery is not able to drive the load, it will open that output, shutting down the motor controller.

The "Throttle reduce" outputs nromally do not affect the throttle. Should the BMS decide that the battery is nearly empty, it will srat shunting the throttle, reducing the available motor drive. The resulting sluggishness warns the driver, and prevents high current draw, which would sag the battery voltage.

 

DISCLAIMER
By reading this page you acknowledge that you understand that this application note is just a suggestion, and that you will not hold Elithion responsible for its accuracy or appropriateness in you application, and that Elithion is not responsible for the fact that other manufacturers change their products in a way that may make these suggestions no longer applicable.
 
© 2008~2024 Elithion™, Inc.. All rights reserved. The Elithion brand and the 'ə' (upside down 'e') logo are Trademarks of Elithion Inc.
Page published on: Nov 08 2019.      Installation manual